Skip to content

Primary Service

CMM Calibration and Repair


Request a quotation for your make, model and axis travel.

Request a quotation

A written quotation is returned by email.

Calibration versus verification

Calibration establishes the relationship between indicated and reference values with a stated uncertainty. What most shops order is performance verification: a pass/fail test against ISO 10360-2 or ASME B89.4.1, run alongside geometric adjustment.

Where the controller allows it, the volumetric error compensation map is updated after adjustment. OEM-locked maps limit what can be changed in the field.

What a visit covers

Cleaning and inspection open the visit; an as-left certificate closes it, with geometry and length measurement error testing in between.

  • 01

    Scale and reader head

    X, Y and Z scales are cleaned and inspected; reader head output is checked and adjusted where needed.

  • 02

    Air bearings and airlines

    Bearing condition and supply air quality are checked before geometry testing begins.

  • 03

    Geometry

    Straightness, linearity and squareness are checked in the XY, ZX and ZY planes.

  • 04

    Length measurement error

    105 measurements across five test lengths and seven positions, per ISO 10360-2.

  • 05

    Probing error

    Tested per ISO 10360-5 against a calibrated test sphere separate from the qualification reference sphere.

Sequence of a visit

  • 01

    Thermal soak

    Artifacts and machine are allowed to stabilize to the specified environment before testing starts.

  • 02

    As-found test

    Length measurement error and probing error are recorded before any adjustment is made.

  • 03

    Adjustment

    Geometric correction and compensation updates are applied where the controller supports them.

  • 04

    As-left certificate

    Final results are issued with reference standards, uncertainty and the decision rule applied.

Why Minneapolis CMM Calibration and Repair

  • 01

    As-found is preserved

    Data is captured before adjustment so an impact assessment can be run if needed.

  • 02

    Repair and calibration together

    Probe, scale, bearing and drive repair are handled without a second site visit.

  • 03

    Environment checked first

    Room temperature and gradient are confirmed before an acceptance test is scheduled.

Coverage across Minnesota and the Greater Midwest

Service area covers Minneapolis and the surrounding metro, with scheduled travel to the named markets listed on this site.

Discuss CMM Calibration Requirements

Send the controller type and last calibration date to begin.

A written quotation is returned by email.